Steps to set chiller temp (thermostat model AVE-2000)
  1. Press and hold set button for 3-5 secs. (_ _ _ will appear)
  2. Click 'up' then 'star' button, 'up' then 'star', 'up' then 'star'. (1 1 1, this is the default password and F01 menu will appear)
  3. While in F01 menu, click 'star' button, the present cut in setting will show. Click 'up' or 'down' button to choose the temperature at which your chiller will start to run. Click 'set' button once. (the display will blink and goes back to F01)
  4. Now while in f01 menu, click 'up' to F02, click the 'star' button, this is the cut off temperature setting at which the chiller will stop sunning. Click 'up' or 'down' button to choose the ideal temperature you want the chiller to chill down to. Click 'set' button once. (the display will blink and goes back to F02)
  5. While in F02, click and hold 'set' button 3-5 secs. (present tank temperature will display, your setting is memorised)
  6. For function F03, its thermostat calibration, you can calibrate the temperature between tank and thermostat, from -5 to +5 degrees. (ignore it)
  7. F04 is the time delay in minutes when the chiller is switch on. (ignore it)
  8. F05 is the defrosting cycle (not in use for chiller application, its being set to 0)
  9. F06 is the defrosting cycle timing (not in use for chiller application, its being set to 0)
  10. F07 is the alarm setting (not in use, by default remain at 20)
  11. F08 is the setting for function between chilling for chiller application or heating for heaters (its being set to 0 for chiller and 1 for cut off device reef saver for lighting)
  12. P01 to P03 is the password setting, you can set your password for the thermostat if you want to. (ignore it)
  13. To set F03, F04, F05, F06, F07, F08, P01, P02 or P03, the follow the steps mentioned aboved.

Here are the quick reference settings:

  • F01- cut in temperature
  • F02- cut out temperature
  • F03- remains at 0
  • F04- remains at 3 or 0
  • F05- Remains at 0 (or set to 0)
  • F06- Remains at 0 (or set to 0)
  • F07- remains at 20
  • F08- 0 for chiller or 1 for reef saver (cut off device for lighting)
  • p01- 1 (password)
  • P02- 1 (password)
  • P03- 1 (password)